ISO 20816 Vibration Severity Zones: Setting Alarm Limits
A vibration limit copied from a chart is only as good as the scope behind it. ISO 20816-3:2022 covers coupled industrial machines above 15 kW, running at 120 to 30,000 r/min, measured in situ. A motor, a fan and a pump in one plant room can each need a different answer.
The ISO documents consulted for this guide to ISO 20816 vibration severity zones are previews that stop before the zone tables, so every vibration limit and alarm formula below comes from a named vendor page.
TL;DR: ISO 20816-3:2022 covers coupled industrial machines above 15 kW, at 120 to 30,000 r/min, measured in situ (ISO preview, 2022). Its covered list names motors and fans, not pumps. Confirm scope and measurement points first, then verify any vendor limit against the full standard.
Which Standard Covers Your Pump, Fan or Motor?
ISO 20816-3:2022 covers various coupled industrial machine types with a power above 15 kW and speeds between 120 r/min and 30,000 r/min, measured in situ. Its list names electric motors with flexible couplings and, subject to a note, blowers and fans. Pumps are not on that list.
Check what the standard covers before you copy its numbers onto a pump or a fan.
The document is a first edition dated 2022-10. It cancels and replaces ISO 10816-3:2009 and ISO 7919-3:2009, with their 2017 amendments (ISO 20816-3, 2022). A national standards catalogue entry gives its publication date as 5 October 2022. If your site procedure still cites ISO 10816-3, review it.
| Your machine | Where the documents point |
|---|---|
| Electric motor, flexible coupling | ISO 20816-3, list item f) |
| Motor rigidly coupled to a machine covered by another ISO 20816 part | That part or ISO 20816-3 |
| Blower or fan | ISO 20816-3, list item j), read with Note 3 |
| Pump with impeller on, or rigidly attached to, the motor shaft | ISO 10816-7, whole coupled unit |
| Rotodynamic pump with a flexibly coupled motor | ISO 10816-7 for the pump only |
| Reciprocating machine, or one solidly coupled to it | Excluded by item n), which refers to ISO 10816-6 |
Every row assumes the machine also meets the relevant document's power, speed and type limits.
The scope of ISO 20816-3 starts above 15 kW. For small motors, Machvory (2026) says the trend against baseline is often the most useful evaluation tool.
Pumps: start with ISO 10816-7
ISO 10816-7:2009 addresses rotodynamic pumps for industrial applications with nominal power above 1 kW. Item o) of ISO 20816-3 excludes "rotordynamic pumps and any integrated or solidly coupled electric motors where the impeller is mounted directly on the motor shaft or is rigidly attached to it" and refers to ISO 10816-7. Read that item alongside the covered list, which names no pumps.
Coupling decides how far the pump document reaches. With an integrated motor, or an impeller shaft rigidly connected to the motor shaft, ISO 10816-7 applies to the whole unit. With a flexibly coupled motor, it applies to the pump only. ISO 10816-7 sends separately mounted drivers to ISO 10816-3, which ISO 20816-3 has since replaced.
ISO 10816-7 also excludes some pumps: reciprocating and rotating positive displacement types, reciprocating-engine-driven pumps, and solids handling, slurry and submersible pumps. Pumps above 1 MW in hydraulic power generating and pumping plants are out too (ISO 10816-7, 2009).
Fans: read Note 3
Note 3 of ISO 20816-3 states: "The vibration criteria presented in this document are generally only applicable to fans with power ratings greater than 300 kW or fans which are not flexibly supported." Recommendations for other fans, including lightweight sheet-metal designs, are to be prepared as circumstances permit.
Until then, the note says the manufacturer and customer can agree classifications using previous operating experience, and it points to ISO 14694 (ISO 20816-3, 2022). For a smaller, flexibly supported fan, write that agreement down before you configure an alarm.
How Should You Measure Vibration for ISO 20816?
ISO 20816-3 Clause 4.2 places non-rotating measurements on bearings, bearing support housings or other structural parts that respond significantly to forces from the rotating elements. The location should represent the overall vibration of the machine. Thin or flexible surfaces, such as fan covers or cowlings, should be avoided.
The clause typically calls for two orthogonal radial locations on each bearing cap or pedestal. Vertical and transverse directions are usually preferred on horizontal machines. On vertical or inclined machines, one location must be the one with the maximum reading. In some cases, an axial measurement is also recommended.
For monitoring, Clause 4.3 requires equipment that measures broad-band r.m.s. vibration with flat response from at least 10 Hz to 1,000 Hz. For machines approaching or below 600 r/min, the lower limit must not exceed 2 Hz. Check your sensor against that range, using our vibration sensor selection guide as a starting point.
For pumps, ISO 10816-7 asks for measurements once the rotor and main bearings reach normal steady-state temperatures. The pump should run at nominal flow, head and speed, within its preferred operating range. Its Table A.1 and A.2 criteria apply to radial vibration on all bearings and axial vibration on thrust bearings (ISO 10816-7, 2009).
Machvory (2026) raises two practical traps:
- Peak against r.m.s. Machvory's zone tables use r.m.s. Multiplying a peak value by 0.707 is exact only for a single sinusoid, so it's only an estimate on a real motor.
- Mounting. A sensor bolted to a flat surface transmits high frequencies better than a magnetic one on thick paint. Use the same point every time so trends remain comparable.
What Are the Zone Boundaries in mm/s RMS?
ISO 20816-3 calls for broad-band r.m.s. measuring capability for monitoring, but its preview ends before the zone tables. The contents list "Evaluation zones" and "Evaluation zone limits" without their text. The zone wording and values here therefore come from vendor pages; confirm them in the full standard.
The same velocity reading can fall in different zones on different supports.
Fabrico (2026) describes the four zones this way:
- Zone A: newly commissioned machines normally fall here.
- Zone B: acceptable for unrestricted long-term operation.
- Zone C: unsatisfactory for continuous operation; the machine may run for a limited period until remedial action can be scheduled.
- Zone D: severe enough to be considered likely to cause damage.
Fabrico also says the highest radial value sets the zone.
Group and support come first
Vendor pages split machines into two groups. Group 1 means above 300 kW, or electrical machines with a shaft height of 315 mm or more. Group 2 means above 15 up to 300 kW, or electrical machines with shaft heights from 160 mm to below 315 mm (Machvory, 2026). Machvory defines shaft height as the distance from the foot mounting surface to the shaft centreline.
Support is a separate choice: rigid or flexible. Fabrico, Torck and Machvory (all 2026) call a support rigid in a given direction when the lowest natural frequency of the machine and its support in that direction is at least 25% above the main excitation frequency, usually running speed. Otherwise it is flexible. Fabrico and Machvory add that the same machine can be rigid vertically and flexible horizontally. Machvory references ISO 10816-3:2009 for the rule. The ISO 20816-3 preview shows only the heading "Classification according to support flexibility", so the rule is unconfirmed there. Don't count three vendor pages as independent confirmation. Don't assume a concrete plinth settles the question, either.
Four pages print these numbers, but they do not amount to four confirmations. Machvory labels its table ISO 10816-3:2009 Annex A, says ISO 20816-3:2022 revised that document, and tells readers to check the current edition. Torck (2026) heads its table ISO 20816-3:2022 Annex A, yet credits fabrico.io for its Group 2 rigid values. Torck also limits its zone values to steady operation at rated speed, excluding run-up and load changes. Wertek AI says it checked against three secondary sources, Fabrico among them.
Wertek lists fans and blowers among its Group 2 examples. Group 2 sits below Note 3's 300 kW mark, so under Note 3 the ISO criteria generally apply to such a fan only if it is not flexibly supported. For pumps, work from ISO 10816-7 and its own tables; don't treat this chart as a pump limit.
How Should You Set Alarm and Trip Limits?
ISO 20816-1:2016 lists "Setting of ALARMS" (6.4.2) and "Setting of TRIPS" (6.4.3) in its contents, but the preview omits both texts. ISO 20816-3 also lists "Operational limits" (6.5), "General" (6.5.1), "Setting ALARM values" (6.5.2) and "Setting TRIP values" (6.5.3), all without text in the preview. The rules below are vendor accounts. Verify them in your licensed copy before they reach a protection system.
A baseline taken at one marked point under normal load is what later readings are judged against.
Fabrico's alarm formula
Fabrico (2026) says to set the alarm at the machine's steady baseline plus 25% of the upper limit of Zone B. The alarm should not normally exceed 1.25 times that Zone B limit. Fabrico presents this as ISO 20816-3's rule; we couldn't confirm it in the ISO preview.
Its example is a Group 2 motor on a rigid base:
- Zone B ends at 2.8 mm/s, so the step is 0.7 mm/s.
- A baseline of 1.2 mm/s gives an alarm at 1.9 mm/s.
- No alarm should sit above 3.5 mm/s.
Now suppose the baseline were 3.0 mm/s. By our arithmetic on Fabrico's figures, 3.0 + 0.7 gives 3.7 mm/s, above the 3.5 mm/s ceiling. That baseline already sits in Zone C on this row. Investigate the machine rather than setting a higher alarm.
Fabrico says to revise the alarm whenever the baseline changes, for example after an overhaul.
Fabrico's trip ceiling
In Fabrico's account, trip limits protect mechanical integrity and do not follow the baseline. Fabrico keeps them no higher than 1.25 times the upper limit of Zone C: 5.6 mm/s for Group 2 rigid and 8.9 mm/s for Group 1 rigid (Fabrico, 2026). The page words this as the standard's recommendation, with the same verification gap.
Machvory's looser wording
Machvory (2026) gives no formula. It says alarm values should be set for each machine against a baseline from experience at that measurement point, generally not far above the upper limit of Zone B. Trip values relate to mechanical integrity and generally lie in Zone C or D.
Before wiring an automatic trip, Machvory says to weigh the risk of stopping the process suddenly.
Why Track the Change From Baseline?
ISO 20816-3 frames its guidelines around steady running vibration values and changes in those values. ISO 20816-1 likewise presents general evaluation criteria as both magnitude and change of vibration. A reading can deserve attention before it crosses a zone boundary.
Fabrico (2026) calls any step, up or down, larger than 25% of the B/C boundary significant: 0.7 mm/s for Group 2 rigid and 1.1 mm/s for Group 1 rigid. It advises a diagnostic check even if the zone hasn't changed. Fabrico attributes this rule to ISO 20816-3; we couldn't confirm it in the ISO preview.
A worked reading, with its limits
Machvory (2026) gives an example it calls illustrative, not plant data. A 75 kW motor drives a cooling water pump at 2,970 r/min on a foundation assessed as rigid. Machvory applies its Group 2 rigid values, from the table it labels ISO 10816-3:2009.
- Drive-end horizontal velocity rises from 1.8 to 3.1 mm/s r.m.s.
- The increase is 1.3 mm/s, about 72%.
- The axial reading moves only from 1.4 to 1.6 mm/s.
- At 3.1 mm/s, the motor falls in Zone C.
Machvory reads the pattern as a pointer to check the spectrum, for example for unbalance or looseness, not as a diagnosis. By our arithmetic, the 1.3 mm/s rise also exceeds Fabrico's 0.7 mm/s step. The example doesn't state the coupling type, so settle scope before borrowing it.
Machvory then changes the assumptions. On a flexible steel frame, 3.1 mm/s would fall in Zone B. If the display showed a peak value from a near-sinusoidal signal, the r.m.s. value would be about 2.2 mm/s, also Zone B on the rigid row. Support class and detector mode can each change the verdict.
What Can an ISO 20816 Vibration Zone Not Tell You?
ISO 20816-3 covers machines that can have gears or rolling element bearings, but it does not address diagnostic evaluation of their condition. It says condition is generally assessed from shaft vibration, structural vibration and specific frequency components. Those components do not always relate to the broadband severity values.
The requirements of ISO 20816-3 also apply only to vibration produced by the machine set itself, not vibration transmitted from external sources. If a neighbouring machine shakes your pedestal, separate that contribution before judging the zone.
Bearings need their own methods. Torck (2026) recommends trending the envelope spectrum at bearing defect frequencies. Enco says a developing defect on slow equipment releases little energy at conventional frequencies. It adds that high-frequency demodulation, shock pulse and ultrasound usually find it sooner.
Treat acceptance separately. Machvory (2026) says the zone boundaries are not intended as acceptance specifications; supplier and purchaser agree criteria for new machines. Fabrico (2026) reports that acceptance values for new machines have historically sat in Zone A or B, normally within 1.25 times the A/B boundary.
What Should You Record Before Enabling an Alarm?
ISO 20816-3 Clause 4.2 requires the specific measurement locations and directions to be recorded with the result. We suggest adding:
- Machine type, power, speed and coupling
- Governing document, group and support class in each direction
- Frequency range, detector mode and baseline conditions
- Alarm and trip values, with the source of each rule
For instrument checks, see our guide to sensor calibration and drift. For wider selection questions, start with the complete guide to industrial sensors.
Frequently Asked Questions
Does ISO 20816-3 apply to pumps?
Its list of covered machine types, a) to j), does not name pumps. Exclusion item o) covers rotodynamic pumps and integrated or solidly coupled motors with the impeller on, or rigidly attached to, the motor shaft, and refers to ISO 10816-7. ISO 10816-7:2009 addresses rotodynamic pumps above 1 kW.
Which electric motors does ISO 20816-3 cover?
The covered list includes electric motors of any type with a flexible coupling, within its scope (above 15 kW, 120 to 30,000 r/min, measured in situ). A motor rigidly coupled to a machine covered by another part of ISO 20816 may be assessed against that part or against ISO 20816-3.
Does ISO 20816-3 apply to every fan?
Blowers and fans are on the covered list, but Note 3 narrows the criteria. They generally apply only to fans rated above 300 kW or fans that are not flexibly supported. For other fans, the manufacturer and customer can agree classifications from operating experience, and the note also points to ISO 14694.
Where should you measure vibration under ISO 20816-3?
Clause 4.2 puts measurements on bearings, bearing support housings or other structural parts that respond significantly to rotor forces. Avoid thin or flexible surfaces such as fan covers. Typically, each bearing cap or pedestal needs two orthogonal radial locations, and in some cases an axial measurement is also recommended.
Can an ISO 20816 zone diagnose a bearing fault?
ISO 20816-3 says it covers machines that can have gears or rolling element bearings but does not address diagnostic evaluation of their condition. It also says specific frequency components do not always relate to its broadband severity values. Use diagnostic methods when you suspect a bearing or gear fault.