SSI vs BiSS vs EnDat: Choosing an Absolute Encoder Interface
Absolute encoders report position as a number, and the interface decides how that number reaches the drive. Three serial interfaces dominate the comparison tables: SSI, BiSS-C and EnDat. They look alike on a wiring diagram but differ in speed, error checking, openness and what else the cable can carry.
If you are still deciding between absolute and incremental feedback, start with Absolute vs Incremental Encoders. For the wider picture, see the industrial sensors guide.
TL;DR: SSI is one-way and point-to-point, limited to 2 Mbit/s (Novanta). BiSS-C keeps SSI's hardware but adds delay compensation, CRC checking and a two-way channel, and it is open. EnDat is HEIDENHAIN's bidirectional interface and is listed as not open. Choose by what your drive supports, cable length and whether you need parameter access.
What Do SSI, BiSS and EnDat Have in Common?
All three clock position out of an encoder over a serial link, with the master (a servo drive or controller) driving the clock. In the SSI and BiSS pattern the sensor keeps updating an output register. When the master sends its first clock pulse, the sensor freezes the register and puts the most significant bit on the data line. The master clocks until every bit is out, and then the sensor resumes updating (Novanta).
Clock and data run as differential signals on twisted-pair cable, and the electrical characteristics conform to RS-422/485 (Novanta). So the cable looks much the same in all three.
The three interfaces share a clocked, differential link; the differences sit in what rides on it.
Renesas describes serial encoders as well suited to point-to-point connections but not to coordinated multi-axis systems where several encoders are used at once (Renesas). It lists fieldbus and Ethernet as the alternatives for that case. This article covers the serial group only. For the network side, see EtherCAT vs PROFINET.
Renesas's prose calls SSI and BiSS "the most used serial protocols", yet its comparison table sets them beside EnDat and HIPERFACE (Renesas). Read the prose as emphasis, not a ranking of EnDat.
SSI: Simple and One-Way
Synchronous Serial Interface is point-to-point, so slaves cannot be bussed together. It is unidirectional, with data flowing only from slave to master. A master therefore cannot send configuration data to a slave. Novanta puts the speed limit at 2 Mbit/s (Novanta).
That limit is an upper bound, and Renesas lists less. Its table gives 1.5 MHz for "SSI + Sine/Cos", with 6 to 8 wires and no cable length compensation (Renesas). The two papers measure different things in different units, so treat both as ceilings, not guarantees.
For error detection, many SSI devices send each reading twice, and the master compares the transmissions. Parity checking improves detection further (Novanta). Parity can still miss corruption that flips multiple bits, which is the gap a CRC closes.
Novanta says much longer cables work at lower bit rates (Novanta). None of the sources gives a maximum SSI cable length, so take that figure from the encoder datasheet.
Is SSI open? The sources disagree. Novanta names SSI as one of two serial interfaces that are open and free of licensing expense (Novanta). Renesas's prose calls SSI and BiSS open source. Its table, though, marks "SSI + Sine/Cos" as not open, with a license available (Renesas). The table column covers SSI combined with sin/cos, which may explain the difference. Check the licensing terms for the exact variant you plan to buy.
BiSS-C: SSI Hardware With More Capability
BiSS-C is the current version of BiSS, and Novanta describes older revisions as essentially obsolete. It is compatible with SSI hardware and recovers easily from instantaneous data loss during operation (Novanta). Renesas says the RZ/T2M's encoder peripheral supports BiSS-C and not B mode (Renesas).
What it adds over SSI:
- Speed and delay compensation. Novanta quotes up to 10 Mbit/s on a 10 meter cable. Within each data cycle the master learns and compensates for line delays, which enables 10 Mbit/s with cable lengths up to 100 meters (Novanta). The plain 10 Mbit/s figure applies to the 10 meter cable.
- CRC error checking. BiSS-C uses a CRC with a 16 or 32 bit polynomial instead of double transmissions (Novanta).
- Status in the same frame. Sensor data can be split into several channels, so position and operational status travel together (Novanta).
- Optional two-way communication. BiSS-C is most often used one-way, like SSI. It can also exchange parameters without interrupting sensor data. The master takes the last logic level on the clock line at the end of a cycle as a control or data bit, so parameters can be set over several cycles (Novanta).
- Optional bussing. Devices can be chained, and the data from all slaves is clocked out to the master in one continuous frame (Novanta).
Delay compensation, not the cable alone, is what supports 10 Mbit/s at 100 meters.
Novanta adds that bidirectional communication and bussing are not typically used in motion control applications. Speed and sturdier error checking carry most of BiSS-C's value. Fast transfer means low latency, which Novanta ties to high-performance motion control (Novanta). The two-way channel still earns its place in motor feedback, where Novanta calls parameter exchange without interrupting data transmission critical for digital control.
On openness, Novanta says BiSS-C is open and free from licensing expense. Renesas agrees in both its prose and its table (Renesas).
EnDat 2.2: Bidirectional and Vendor-Controlled
EnDat 2.2 comes from HEIDENHAIN, and the guide describes the master as the part that controls communication with EnDat 2.2 encoders (HEIDENHAIN). The Renesas table lists it as bidirectional and synchronous, point-to-point, with cable length compensation, 6 to 12 wires and not open (Renesas).
Its speed needs a careful reading. The Renesas serial table lists 4 MHz. A second Renesas table, covering what the RZ/T2M chip supports, lists EnDat 2.2 from 100 kHz to 16.7 MHz. The second describes one chip's range, and the first sits in a general comparison. Do not read 4 MHz as EnDat's capability. The HEIDENHAIN guide gives no maximum clock, so confirm the figure for your encoder and master.
Communication between the control and the encoder is based on mode commands, and in purely serial operation only the position is transferred, without the EnDat 2.2 additional data (HEIDENHAIN).
The guide splits implementation into four stages:
- the physical layer;
- communication based on mode commands;
- complex processes such as memory access; and
- integration into the controller.
EnDat is more than a clock and a data line. HEIDENHAIN recommends using one of the available EnDat Masters for stage 1 (HEIDENHAIN). A master can run on a microcontroller or on an FPGA or ASIC. Microcontroller solutions suit relatively low clock frequencies, while FPGA or ASIC integration is usually chosen when high transmission frequencies are wanted with purely serial transmission.
To get the EnDat 2.2 documentation package, the guide directs you to a contact form at www.endat.de. It also lists functional safety documents: a catalog of measures, requirements for position value comparison, a supplementary catalog of measures for SIL 3, and the use of a non-functionally-safe EnDat 2.2 master. The sources give no safety figures beyond those document titles, and they cover no safety options for SSI or BiSS.
Side by Side
Where the sources disagree, the cell says so, because a single speed figure would mislead.
| SSI | BiSS-C | EnDat 2.2 | |
|---|---|---|---|
| Open protocol | Novanta: yes. Renesas table ("SSI + Sine/Cos"): no, license available | Yes | No (Renesas) |
| Connection | Point-to-point | Bus or point-to-point | Point-to-point |
| Direction | Unidirectional | Bidirectional (optional) | Bidirectional |
| Speed | Up to 2 Mbit/s (Novanta); 1.5 MHz (Renesas, SSI + Sine/Cos) | 10 Mbit/s on 10 m; 100 m with delay compensation (Novanta) | 4 MHz (Renesas Table 2); 100 kHz to 16.7 MHz (Renesas, RZ/T2M) |
| Cable length compensation | No (Renesas) | Yes | Yes |
| Wires (Renesas) | 6 to 8 | 6 | 6 to 12 |
| Error checking | Double transmission, optional parity | CRC (16 or 32 bit) | Not covered by the sources |
The Renesas chip table lists BiSS-C at 80.12 kHz to 10 MHz (Renesas). That describes one chip's support, not the protocol's full range. The chip table also carries notes on 1-to-1 and bus connection, but the source text is flattened and the notes cannot be reliably assigned to a protocol column, so rely on the connection row above (Renesas Table 2 and Novanta). The sources give no prices or license fees for any of the three.
How Do Parallel Outputs and Gray Code Fit In?
Parallel is the alternative to serial, and Renesas notes that parallel encoder output is typically Gray code (Renesas). Encoder Products Company calls Gray code the most popular absolute encoder output type because it prevents data errors that can occur with natural binary during state changes. In a highly capacitive circuit or a sluggish system, a natural binary change from 0011 to 0100 could make the counter or PLC see 0111. With Gray code only one bit changes from one position to the next (Encoder Products Company).
The cost is a conversion step. The same paper describes converting Gray code to natural binary with exclusive-OR logic, which in a PLC means a ladder of XOR rungs (Encoder Products Company).
Parallel wiring has its own drawbacks. Renesas says it suits very high-speed applications where latency must be minimal, but it needs more wires, which adds complexity and cost and lowers reliability (Renesas). A serial interface sends all data bits in series on a single twisted pair instead.
How Do You Choose Between Them?
Work through these questions in order; the first often decides it. Renesas says its RZ/T2M chip can run EnDat 2.2, BiSS-C and other protocols without external protocol hardware (Renesas), but that describes one chip, so check your own drive's manual.
Start with what the drive already supports; the encoder interface follows from it.
- What does the drive or controller already support? If it speaks only one of the three, the choice is made.
- Do you need an open interface? BiSS-C is open. EnDat is listed as not open. For SSI, check the variant, as discussed above.
- How long is the cable, and how fast must you read? BiSS-C's delay compensation supports 10 Mbit/s at up to 100 meters, and EnDat also lists cable length compensation. SSI does not, and the sources give no maximum SSI cable length.
- Must you configure the encoder over the same cable? SSI cannot send data to the encoder. BiSS-C and EnDat can.
- Is the machine safety-rated? EnDat has dedicated functional-safety documents. The sources do not cover safety options for SSI or BiSS, so ask the vendor.
- Do you need many encoders on one link? Serial links are a weak fit, per Renesas. Look at fieldbus or Ethernet encoder protocols instead.
Cabling matters as much as the protocol. Differential pairs help only if shield and ground are right, so read cable shielding and grounding for sensor signals before routing an encoder cable beside a motor lead.
What Mistakes Should You Avoid?
Treating BiSS and SSI as a free swap. The hardware is compatible, but the master must speak BiSS-C to get delay compensation and CRC.
Copying one speed figure from a chart. The sources disagree for SSI and EnDat, as shown above. Use the datasheet for the exact encoder and the manual for the exact drive.
Assuming SSI is free of licensing in every form. Novanta and the Renesas table disagree. Verify the variant.
Underestimating EnDat integration. HEIDENHAIN's own guide lists four implementation stages and recommends a ready-made master.
Frequently Asked Questions
What is the main difference between SSI, BiSS and EnDat?
SSI is a one-way, point-to-point serial link. BiSS-C is hardware compatible with SSI but adds line-delay compensation, CRC error checking and two-way communication (Novanta). EnDat is HEIDENHAIN's bidirectional synchronous interface, and the Renesas table lists it as not open (Renesas).
Is BiSS compatible with SSI?
BiSS-C is hardware compatible with standard SSI, according to Novanta (Novanta). The master must still speak the BiSS-C protocol to get delay compensation, CRC checking and the two-way channel.
Is EnDat an open protocol?
The Renesas comparison table lists EnDat as not open and BiSS as open (Renesas). Novanta names BiSS-C and SSI as the only two serial interfaces that are open and free of licensing expense (Novanta).
Why do absolute encoders use Gray code?
Only one bit changes between adjacent positions, so a mid-transition misread cannot jump to a distant value as it can in natural binary. Encoder Products Company gives 0011 to 0100 being misread as 0111 as the example (Encoder Products Company).